Skip to content

Planning application · ISLINGTON/P2025/3632/S73

ISLINGTON/P2025/3632/S73Application under consideration

Removal of condition to raise coal vault door opening height by 100mm, replacing concrete lintel at Gibson Square.

46, Gibson Square, N1 0RA

St Mary's & St James' ward · Islington

Category
Extensions & Enlargements
Scale
Minor 2/10

Overview

As lodged with the council

We wish the condition to be removed, because the results of further site investigations support our original proposal to raise the coal vault door opening height. As part of clearing other conditions for the Listed Building consent, a site investigation has been carried out of the coal vault entrance door lintel. It was revealed that there is no existing historic brick arch above the entrance, as would be expected if it was original, and instead a concrete lintel was found. Please refer to Chelmer Global Ltd Factual report: 'FACT14165 (rev1).pdf' page.3 'Sketch Site Plan' and page.14 'Photograph 5 - Opening Up 1 (OP1)'. The existing lintel to this internal coal vault is positioned lower down from the vaulted arch ceiling behind, than the higher positioned lintel to the external coal vault. Please refer to existing drawing GB-SA-DR-A-3010-2001 view: 'East Front Lightwell' and GB-SA-DR-A-3010-2001. We propose that the entrance opening height to be raised by 100mm by replacing the concrete lintel in accordance with the structural engineer's design, method and specification. Please refer to detail drawing GB-SA-DR-A-4030-5002, and structural engineer's documents: '4350.02 - Design Intent Report.pdf' and '4350 - Specification.pdf'. This change to the internal coal vault opening would bring it in line with external coal vault opening and the head would remain below the vaulted ceiling behind. Please refer to proposed drawings GB-SA-DR-A-4030-3003 view: 'East Front Lightwell' and GB-SA-DR-A-4030-2001. The proposed height of the door opening would be 1.7m, which will remain clearly subordinate to the height of the main doors of house and not alter the vault's historic characteristically low entrance height. Please refer to other drawings updated accordingly: GB-SA-DR-A-3010-1209 - PLAN LOWER GROUND LEVEL EXISTING GB-SA-DR-A-3010-1210 - PLAN GROUND LEVEL EXISTING GB-SA-DR-A-3010-2001 - ELEVATION WEST EXISTING GB-SA-DR-A-3010-3001 - SECTIONS 1 EXISTING GB-SA-DR-A-3010-3002 - SECTION 2 EXISTING GB-SA-DR-A-3010-3003 - SECTION 3-4-5-6 EXISTING GB-SA-DR-A-4030-1009 - PLAN LOWER GROUND LEVEL PROPOSED GB-SA-DR-A-4030-1010 - PLAN GROUND LEVEL PROPOSED GB-SA-DR-A-4030-2001 - ELEVATION WEST PROPOSED GB-SA-DR-A-4030-3001 - SECTION 1 PROPOSED GB-SA-DR-A-4030-3002 - SECTION 2 PROPOSED GB-SA-DR-A-4030-3003 - SECTION 3-4-5-6 PROPOSED GB-SA-DR-A-4030-5002 - SECTION DOOR HEAD CONSTRUCTION EXISTING & PROPOSED Further photos of door opening lintel: 46GS_SI_CVbefore.jpg 46GS_SI_CVhole2.jpg 46GS_SI_CVhole3.jpg 46GS_SI_CVholeunder1.jpg

The headline is a plain-English summary written with AI from the council record.

Keep reading

Track this application

How do I track planning application ISLINGTON/P2025/3632/S73?

Follow it on City Scope. This page is checked against the Islington planning register and shows the latest status, decision and documents for ISLINGTON/P2025/3632/S73. To comment on the application, use the Islington planning portal.